XOS5200iD 5200-Watt Dual Fuel Inverter Generator
SKU: XOS5200iD
Barcode: 850055834750
- EPA, PGMA 300 Compliant
- ULTRA - Lightweight: Just 80.5 lbs
- CO Sensor With Auto Shutdown: Monitors and reacts to carbon monoxide (CO) levels
- Dual Fuel: Offers the choice of operating with gasoline or propane or both with Fuel Sense Technology
- 2.6 Gallon Tank, up to 12.0 Hour Runtime
- 20 lbs. Propane Cylinder, up to 26.0 Hour Runtime
- 5200 Starting / 4200 Running Watts (Gas)
- 4700 Starting / 3800 Running Watts (Propane)
- High Performance 224cc OHV Engine
- Fuel Sense Technology: Extended continuous runtimes of up to 38.0 hrs with Fuel Sense Technology
- Pure Power: <3% THD of clean power
- Low Idle Technology: Adjusts RPM based on demand, saving fuel
- LED Equipped Control Panel & Parallel Capability
- Quiet Operation: As low at 62 dB - ideal for home, camping, tailgating & RV
- Digital Data Center: Provides voltage, frequency, hours, power & fuel levels,output/overload/oil level status along with fuel saving low idle and reset functions
Couldn't load pickup availability
XOS5200iD 5200-Watt Dual Fuel Inverter Generator
Description:
The A-iPower XOS5200iD 5200-Watt Dual Fuel Inverter Generator, with Fuel Sense Technology, is EPA and PGMA 300 compliant. Offering the choice of operating with gasoline, propane, or both, the unit offers 5200 starting watts and 4200 running watts on gas and 4700 starting watts and 3800 running watts on propane.
The 2.6-gallon gas tank provides up to 12 hours of runtime, while a 20-pound propane cylinder offers up to 26 hours of runtime. With the Fuel Sense Technology, extended continuous runtimes of up to 38 hours are possible. The low idle technology adjusts RPM based on demand, which saves fuel.
Lightweight at 80.5 pounds with a high-performance 224cc OHV engine, the unit operates at as low as 62 decibels, making it ideal for home, camping, tailgating, and RVing. It has an LED-equipped control panel and parallel capability with a CO Sensor that monitors and reacts to carbon monoxide (CO) levels, automatically shutting down if necessary.
The Digital Data Center provides voltage, frequency, hours, power and fuel levels, output/overload/oil level status, and fuel-saving low idle and reset functions.
Unboxing & Operation VideoMaintenance Video
Video content is being prepared and will be updated soon.
Stay tuned for more exciting content!
Safety Q&A
1、Where should I place the generator during operation?
Always operate the generator outdoors only. Keep it at least 20 feet (6 m) away from doors, windows, and vents, and at least 5 feet (1.5 m) away from any combustible materials. Place it on a dry, stable surface under a protective cover or canopy to shield it from the weather.
2、What should I know before refueling a generator?
Always turn off the generator and let it cool down completely before refueling.
Use clean, fresh fuel of the recommended grade.
Never refuel while the generator is running or hot, as this may cause fire or explosion.
3、Where should I safely store a generator when not in use?
Store the generator in a cool, dry, and well-ventilated location. Make sure the air vents are not blocked and that it is kept away from any flammable materials.
4、How do I safely transport a generator?
Before transporting, turn off the unit, drain the fuel tank, and disconnect the spark plug. Keep the generator upright during transport, ensure ventilation openings are not blocked, and avoid exposure to heat or moisture.
Setup/Startup
1、How do I connect the generator battery? (For models with electric start)
When you first receive the generator, the negative battery cable is usually disconnected to prevent discharge during storage.
- Locate the negative cable near the top or rear of the battery.
- Attach the loose end of the negative cable to the negative terminal post of the battery and tighten securely with a bolt.
- ⚠ Caution: Avoid touching both the battery terminal and the generator frame with tools or metal objects at the same time to prevent short circuits.
2、What type of engine oil should I use?
Initial use (break-in period): SAE 30, 10W-30, or 5W-30 mineral oil is recommended.
After break-in: You may use either mineral oil or full synthetic oil.
High temperatures (above 95°F / 35°C): 10W-40 is recommended.
3、What type of gasoline should I use?
Use unleaded gasoline with an octane rating of 87 or higher, and with ethanol content of no more than 10% (E10).
⚠ Tip: Lower ethanol content helps extend the life of the carburetor, fuel system, and seals.
4、How do I add fuel and check the oil for the first time?
Before the first startup, fill with the recommended engine oil.
Check the dipstick and ensure the oil level is within the marked range.
When adding oil or fuel, avoid spills, keep away from open flames, and use a dedicated oil/fuel container for safety.
5、How do I start the generator with recoil (pull) start? - Set the breaker and master control switch to OFF.
- Select the fuel type:
Gasoline: Open the gasoline valve → Turn the fuel selector to Gasoline.
Propane: Close the gasoline valve → Turn the fuel selector to Propane → Connect the propane tank and open the valve. - Switch the battery to ON (or “RUN” on some models).
- Pull the recoil cord: Pull slowly until resistance is felt, then pull sharply. Repeat if necessary until the engine starts
6、How do I use the electric start function?
Ensure the battery is properly connected and charged.
Set the fuel switch to the correct position.Turn the start switch to START.
Once the engine starts, release the switch and let it return to RUN/ON.
7、Does the generator need to warm up?
Yes. After starting, let the engine run idle for 1–3 minutes to allow the oil to circulate fully before applying a load.
8、How do I safely connect electrical loads?
Start the generator before connecting any appliances.
Connect higher-wattage devices first (e.g., refrigerator, air conditioner), then smaller devices.
Do not exceed the rated wattage capacity of the generator.
9、How do I start the generator in cold weather?
Use engine oil suitable for low temperatures (e.g., 5W-30).Place the generator in a warmer environment or use an engine block heater if available.Expect longer starting times in freezing conditions — this is normal.tent goes here.
Maintenance
1、How do I change the generator oil?
- Place the generator on a level surface.
- Locate the oil drain bolt at the bottom lip of the crankcase and place a container underneath.
- Use a 12mm wrench to remove the drain bolt and allow the oil to drain completely.
- Reinstall the bolt, remove the oil filler cap, and refill with oil until it reaches the thread level of the cap.
Tip: If the generator is on a flat surface, excess oil will naturally overflow before it is overfilled.
2、How do I drain fuel from the tank? - Turn the fuel valve to the OFF position.
- Place a container under the fuel 3. filter cup (below the valve).
- Remove the cup and turn the valve to ON to drain fuel completely.
Reinstall the fuel filter cup.
3、How should I prepare my generator for long-term storage?
Turn the circuit breaker OFF and run the generator for 3–5 minutes.
Switch the fuel valve to OFF and let the engine run until it shuts down.
Turn the engine/battery switch to OFF.
Drain remaining fuel from the tank and carburetor.
Remove the spark plug, add 2 tablespoons of 10W-30 oil into the cylinder, and pull the recoil starter a few times to lubricate.Reinstall the plug.
Disconnect and remove the battery, then maintain it with a trickle charger.
Store the generator in a cool, dry, and well-ventilated location.
4、How do I maintain the generator battery?
Generator batteries can lose charge within 3–6 months of storage.
Disconnect the battery when not in use.
Use a 12V SLA-compatible trickle charger to keep it charged.
Avoid exposing the battery to extreme heat or cold.
5、How often should I perform generator maintenance?
Before each use: Check fuel level, engine oil, and air filter. Every 50–100 hours of operation: Change engine oil, clean the spark plug, and service the air filter. Long-term storage: Drain fuel completely and store the generator properly.
6、Do I need to replace the air filter, and how often?
Yes. The air filter should be cleaned every 25 hours of use and replaced every 100–150 hours, or more often in dusty conditions.
7、When should I replace the spark plug?
Inspect the spark plug every 100 hours of operation. Replace it if it shows wear, buildup, or damage.
8、How do I prevent stale fuel from damaging the engine?
If the generator will not be used for more than 30 days, add a fuel stabilizer to fresh gasoline or drain the fuel system completely.
How to Contact Us for Further Assistance:
Phone Support: Connect directly with our knowledgeable customer service team at 855-888-3598 for immediate assistance.
Email Support: Send us an email with your inquiry, and our support team will respond promptly.
Live Chat: Use our real-time chat feature to get instant answers to your questions.
XOS5200iD Manual
XOS5200iD Spec Sheet
XOS5200iD Quick Start Guide
6
0
0
0
0
Powers more than we expected
This is a great inverter generator that has started on the first pull every time. My 12 year old son can pull the rope to start easily when we are camping. is is very quiet when running and we can run everything we need. I even used it as a sortof home backup a few weeks ago when our power went out from that storm that came thru here in PA. We recommend it. thanks
Hi Ivan, Thank you for the great review! We’re glad to hear your XOS5200iD has been so reliable — from first-pull starts to quiet camping use and even stepping in during a home outage. It’s wonderful to know it’s powering everything your family needs, and we appreciate the recommendation! ~A-iPower Customer Support Team
Heavy duty! Fantastic shipping.
XOS5200iD inverter generator is powerful and very high quality.
works great
I really like this product. It was delivered to my house in three days and started using it that day. Great prpoduct.
Best inverter generator
We use our new XOS5200iD inverter generator a lot. It runs great and operates on both gasoline and propane. This is definitely the product to buy for power and price!
Gas and Propane Dual Fuel Inverter is Versatile
The XOS5200iD is compact, versatile nature and has the ability to handle a variety of tasks. I use it almost every week and it's a workhorse. Recommended.
New Technology
The new A-iPower XOS5200iD has fuel-sense. This new technology works like this: attached a prpopane tank to the inverter, start it up and the unit will run on LP until the tank is empty then automatically starts to run on gasoline. What a great feature and you never have to worry about running out of fuel. The fuel technology is great and it also is quiet and lightweight with wheels.
what does the remote do
Hi Keith, The remote allows you to start and stop the generator from a short distance away using the electric start system. It’s designed for convenience, so you don’t have to walk up to the unit each time you want to power it on or shut it down. ~A-iPower Customer Support Team
Please Wait ....